RC-DG01 is applied to the safety protection device of Pipelayer. It can prevent the Pipelayer from overloading and operation errors, so that the safe use of the crane can be standardized and scientific. This product adopts new electronic devices, and various performances have been greatly improved. In the display, the display technology of full LCD color dot matrix (Graphic Chinese character) is adopted, and the full English character display interface is adopted. The user is more intuitive, clear and has a good man-machine interface.
System Display
Power supply | DC24V | power | 20W |
Lifting resolution | 0. 1t | Alarm error | <3% |
Protection grade | IP65 | Standard | GB/T 12602-2020 |
screen resolution | 640*480 | Screen dimension | 230 mm *150mm *73mm |
Installation of Display
Installation of Load sensor
Install the load sensor and ATB switch at the fixed end of the lifting rope of the pipe layer.
Installation of Tension Load cell
a.The Load cell is generally installed at the fixed end of the lifting rope of the pipe layer.
b.When installing, do not stick the wire rope on the sensor, and leave a gap about 1mm;
c.Wires need to be fasten, reseve a certain distance for movable parts of the herringbone and the pulley
d.Unscrew the screws ① and ② counterclockwise to get stuck on the luffing wire rope. Tighten it clockwise, and the height of the wire rope from the side pressure is about 3mm
Installation of Angle sensor
Install the signal transmission box
SERVICE AND MAINTENANCE
Do not pull the cable to prevent from damaging, When need to remove the whole machine, pay attention to connectors, in order to avoid pollution, and affect the working.
Non-maintenance people shall not adjust the internal parameters of the instrument. If an abnormality occurs, firstly follow the instructions manual. If still failed, please report to the relevant people.
If crane working conditions are changed, please revise working condition parameters in time to make the crane work properly.
The system is not absolutely to prevent accidents caused by dangerous factors (not operating according to safety regulations). Therefore, the safe operating procedures cannot be ignored during working.
Regularly inspect the system accuracy to ensure crane safety use(inspection period is 4-6 months).
After-Sales Service
Thanks for choosing our products.
In order to make the product work better for you, please read this manual before use. Any problems during operating please feel free to call us
Free repair or replacement during one year warranty period.
For life technical support and after sales service.
One of the following conditions is not covered by the warranty:
Failure caused by flushing with water
Damage caused by collision
Damage caused by incorrect wiring and brutal dis-assembly
Damage caused by other abnormal operating